CCR Maintenance

We provide comprehensive servicing for closed-circuit rebreathers (CCRs). Our certified technicians strictly adhere to established standards to evaluate, maintain, and repair your equipment, ensuring peak operational performance.

As a designated Poseidon Pro Academy, we specialize in Poseidon rebreather systems.

Poseidon CCR Maintenance Service Features

Poseidon MkVI and Se7en rebreathers require scheduled maintenance by an Authorized Service Technician, with a maximum recommended interval of 104 weeks (current service status is indicated via POST Test 55).

As Certified Poseidon Service Technicians, we provide a comprehensive Scheduled Maintenance package, which includes:

  • Thorough cleaning and inspection of all components for wear and degradation

  • Diluent First Stage inspection

  • Oxygen First Stage inspection

  • Diluent Cylinder Valve inspection

  • Oxygen Cylinder Valve inspection

  • Replacement of all O-rings within the breathing loop

  • Bail-Out Valve (BOV) inspection

  • Firmware updates for all electronic components

  • Successful execution of the POST diagnostic test

  • Factory service counter reset

  • Complete loop disinfection utilizing Gigasept

  • All replacement parts and Service Kits are guaranteed genuine Poseidon OEM components.

Should any components outside the standard Service Kit require replacement, we will request written authorization for the additional costs prior to proceeding.

Estimated turnaround time is 30 days from the date of receipt at the Poseidon Pro Academy.

Please ship the complete rebreather system, including:

  • Canister

  • E-Module (E-mod)

  • Battery and Charger

  • Breathing Loop (hoses, counterlungs, T-pieces, and BOV)

  • Cylinders and Valves

  • First Stages and hoses

  • Dive Computer and cable

  • HUD and C-POD (Note: Do not include the BCD, wing, or harness).

You may ship the unit yourself, or package it and let us arrange a courier pickup for your convenience.

As an Authorized Service Center, we are mandated to replace any damaged or degraded parts exclusively with genuine Poseidon OEM components, strictly adhering to factory rebreather guidelines.

Our standard MRO policy mandates the replacement of Oxygen sensors during every service. You may include two new, factory-sealed O2 cells when shipping your CCR, or request specific models. Otherwise, we will install two genuine Poseidon O2 cells. The base service rate does not cover the cost of these cells (please refer to the detailed pricing below).

If any aspect of our service fails to meet operational expectations, we will readjust or repair your equipment at no additional cost within 60 days of the service completion date.

Service Rates

Authorized Poseidon CCR Maintenance Labor (MkVI / Se7en / Se7en+): €299

Complete Se7en / MkVI Service Kit: €339 (Includes):

Diluent First Stage Service Kit

Oxygen First Stage Service Kit

Diluent Cylinder Valve Service Kit

Oxygen Cylinder Valve Service Kit

Bail-Out Valve (BOV) & Second Stage Service Kit

Complete Breathing Loop Service Kit

Scrubber Canister Service Kit

Molex Oxygen Cell (Per Unit): €74.38

Solid-State Oxygen Cell (Per Unit): €512.40

Contact us to receive a customized estimate for your CCR. No maintenance procedures will be initiated without prior approval of the quote.

If you have any questions, please do not hesitate to contact our team.Prices do not include VAT or shipping costs.

CONTÁCTANOS

¿Tienes alguna pregunta o necesitas asistencia? Nuestro equipo está aquí para ayudarte con todas tus consultas. Ya sea que busques más detalles sobre nuestros productos y servicios o necesites soporte, no dudes en ponerte en contacto con nosotros. ¡Te responderemos lo antes posible!

info@tieronesupply.com


Oficina: +34 955 453 220

Tlf. y Whatsapp:

+34 747 41 85 10‬

P.I. PIBO
Avenida de Umbrete 8

41110 Bollullos de la Mitación
Sevilla. SPAIN